【Application】
Customs、Quality inspection agencies、Environmental protection agencies、Public places、Border crossings、Airports、Ports、Entry and exit port、Metallurgy industry、Nuclear power plant。
【Features】
⊙ Detection Area: Divided into eight longitudinal arrangement, can be
received with both sides and
accurately positioned to detect objects.
⊙ Sensitivity and False Positive Rate: Comply with the standard of
GB/T24246-2009.
⊙ Sensitivity Consistency: There is no blind area in the detection
area, uniform, better than the standard
of GB/T24246-2009.
⊙ Radionuclide Identification: The energy range of the radioactive
material can be distinguished from the
naturally occurring radioactive
materials (NORM) and special nuclear material (SNM)
⊙ Dose Rate Analysis: A rough analysis of the dose rate, can determine
the risk levels.
⊙ Overload Characteristic: >100 Sv/h will show alarm.
⊙ Other Detection Ability: Infrared ray correlation device, will
automatically track the sampling
adjustment technology, and automatically
reduce false alarm.
⊙ Alarm Sound: 2 alarm tones can be selected.
⊙ Anti-interference: Using digital filtering, digital pulse and other
advanced technology. More than one
series without interference.
⊙ Management Encryption: Set a password, only with the correct
password to be set the parameters of
the program and the
sensitivity.
⊙ Data Recovery: Can be used to restore the factory settings, such as
improper operation caused by the
loss of data, etc.
⊙ Computer Control: The parameter can be set up by the computer, and
the detection data will be
displayed.
⊙ Networking: Reserved data communication interface to connect with
the computer, and multiple
devices can be controlled by computer
⊙ Anti-impact: Not influenced by external factors, has strong
resistance to collision.
⊙ Safety: Comply with current international safety standards, using
the technology of weak magnetic
field, no damage to the pacemaker wearer,
pregnant women, CD discs, aprons, video tapes, hearing
aids,etc.
【Specification】
Working Voltage:AC 220V
Power:260W
Weight:<600KG
Working
Temperature:-20℃~+40℃
Outline
Size:2170mm(H)×990mm(W)×600mm(D)
Tunnel
Size:2000mm(H)×760mm(W)×600mm(D)